A型適用于(yu)一般橡膠(jiao)(jiao)、合成橡膠(jiao)(jiao)、軟橡膠(jiao)(jiao),多元脂、皮革(ge)、蠟等
C型(xing)適用(yong)于橡(xiang)塑并用(yong)、塑料(liao)中含(han)有(you)發泡劑制(zhi)成的微孔材料(liao)
D型適(shi)用于一般硬橡膠、樹脂、壓克力(li)、玻(bo)璃、熱塑性橡膠、印刷板、纖維(wei)等。
符合標(biao)準DIN53505,ASTMD2240,JISR7215
邵氏(shi)橡膠硬度(du)計是測定(ding)硫化橡膠和塑料制品(pin)硬度(du)的儀器,該儀器有A型、D型、C型三種(zhong)形式
A型和D型分別(bie)適用(yong)(yong)(yong)(yong)于低(di)中硬度和高(gao)硬度材(cai)料的(de)測試。C型適用(yong)(yong)(yong)(yong)于壓(ya)縮為(wei)50%,應(ying)力0.049MPa以上時,采(cai)用(yong)(yong)(yong)(yong)橡塑并用(yong)(yong)(yong)(yong),塑料中含有發泡劑制(zhi)成的(de)鞋用(yong)(yong)(yong)(yong)微(wei)孔(kong)材(cai)料硬度的(de)測試。
本(ben)硬度計執(zhi)行GB/T531-99,GB2411-80,HG/T2489-93,JJG304-2003有(you)關規定(ding)。
刻度盤值:0-100度
壓針行程:0-2.5mm
壓針端壓力:A/C型(xing)0.55N-8.06N,D型(xing)0-44.5N
把(ba)式樣(yang)放置在堅(jian)固(gu)的平(ping)面上(shang)(shang),拿住硬(ying)度(du)計(ji),壓(ya)(ya)(ya)針距離試(shi)樣(yang)邊緣至(zhi)少12mm平(ping)穩的把(ba)壓(ya)(ya)(ya)足壓(ya)(ya)(ya)在試(shi)樣(yang)上(shang)(shang),使(shi)壓(ya)(ya)(ya)針垂直的壓(ya)(ya)(ya)入試(shi)樣(yang),直至(zhi)壓(ya)(ya)(ya)足和試(shi)樣(yang)*接觸(chu)時(shi)1S內讀數。在測(ce)點(dian)相距至(zhi)少6mm的不同位置測(ce)試(shi)硬(ying)度(du)值5次(ci),取其平(ping)均值(微孔材料測(ce)點(dian)相距至(zhi)少15mm)。為(wei)穩定測(ce)試(shi)條(tiao)件,提高測(ce)試(shi)精度(du),應將硬(ying)度(du)計(ji)裝置在配(pei)套生產的同型號測(ce)定架上(shang)(shang)測(ce)定。
5.使用須知
使(shi)(shi)(shi)用(yong)(yong)前(qian)應檢查硬(ying)度(du)(du)計的指針(zhen)(zhen)在(zai)(zai)自(zi)由狀態下(xia)應顯(xian)示(shi)為零(ling),(如(ru)(ru)不(bu)(bu)顯(xian)示(shi)為零(ling),使(shi)(shi)(shi)用(yong)(yong)清零(ling)鍵(jian)ZERO清零(ling))。將硬(ying)度(du)(du)計壓(ya)在(zai)(zai)玻璃(li)板(ban)時,應顯(xian)示(shi)100度(du)(du)(壓(ya)針(zhen)(zhen)端面與壓(ya)腳底面嚴密(mi)接(jie)觸與玻璃(li)板(ban)上)。如(ru)(ru)不(bu)(bu)指示(shi)0和100度(du)(du)時,可(ke)(ke)以(yi)輕微按動壓(ya)針(zhen)(zhen)幾次,如(ru)(ru)仍(reng)不(bu)(bu)顯(xian)示(shi)0和100度(du)(du)時,則(ze)不(bu)(bu)能使(shi)(shi)(shi)用(yong)(yong)。如(ru)(ru)在(zai)(zai)定荷架上使(shi)(shi)(shi)用(yong)(yong)時,可(ke)(ke)以(yi)按動手(shou)柄,使(shi)(shi)(shi)硬(ying)度(du)(du)計在(zai)(zai)砝碼(ma)重(zhong)力作用(yong)(yong)下(xia),硬(ying)度(du)(du)計壓(ya)足和測試(shi)臺(tai)*接(jie)觸,此時數值顯(xian)示(shi)應100±1度(du)(du),可(ke)(ke)以(yi)使(shi)(shi)(shi)用(yong)(yong)試(shi)驗臺(tai)下(xia)兩個調節手(shou)輪微調,如(ru)(ru)仍(reng)調不(bu)(bu)到100±1度(du)(du),同樣不(bu)(bu)可(ke)(ke)以(yi)使(shi)(shi)(shi)用(yong)(yong),做好送廠(chang)方調整(zheng)為宜。
D型硬度(du)計(ji)手持(chi)壓在玻璃(li)上檢驗(yan)零位時(shi)貨裝置在定荷(he)測(ce)定架上調整零位時(shi),必須(xu)在硬度(du)計(ji)壓足下(xia)放(fang)置堅(jian)硬的量(liang)塊(kuai),否則(ze),硬度(du)計(ji)壓頭會壓損(sun)玻璃(li)板,而且很難準確示值。
橡(xiang)(xiang)膠試(shi)(shi)樣應按(an)GB/T631-99的(de)(de)要求(qiu)制備(bei),塑料試(shi)(shi)樣應按(an)GB2411-80的(de)(de)要求(qiu)制備(bei),橡(xiang)(xiang)膠微(wei)孔材料的(de)(de)試(shi)(shi)樣應按(an)GB2489-93的(de)(de)要求(qiu)制備(bei)
在可能的情況下(xia)橡塑試(shi)樣(yang)在測(ce)(ce)(ce)定(ding)前應(ying)按照GB0T2941/GB/T2918的規定(ding)在實驗室標準溫度(du)下(xia)進行調節后再(zai)測(ce)(ce)(ce)定(ding)。當(dang)試(shi)樣(yang)用A型硬(ying)度(du)計測(ce)(ce)(ce)量值(zhi)超過(guo)90度(du)時(shi)(shi),推(tui)薦使用D型硬(ying)度(du)計,當(dang)D型硬(ying)度(du)計測(ce)(ce)(ce)量值(zhi)低于20度(du)時(shi)(shi),推(tui)薦用A型硬(ying)度(du)計。A型硬(ying)度(du)計示值(zhi)低于10度(du)時(shi)(shi)是(shi)不(bu)準確的,測(ce)(ce)(ce)量結(jie)果不(bu)能使用。硬(ying)度(du)計在使用完畢(bi)后,應(ying)擦(ca)凈(jing)裝入儀器(qi)盒內,放置(zhi)干燥處,防止受潮。